Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Tipo de estudio
Intervalo de año de publicación
1.
Clin Lab ; 70(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38623674

RESUMEN

BACKGROUND: The purpose of this study was to determine the staining conditions and appropriate fan1 start time (FAN1ST) for Sysmex SP-50 to produce blood smears (BS) that reflect the true lymphocyte morphology of patient samples. METHODS: Using different start times of fan1, we obtained a set of 84 blood smear slides from 21 blood samples and measured 10,920 lymphocyte areas, which were then converted to compare lymphocyte sizes. We also performed a leukocyte differential count using Sysmex DI-60 on 202 blood smear slides prepared before and after the change in staining conditions and compared the results. RESULTS: The mean lymphocyte sizes at FAN1ST 0 second, 5 seconds, 10 seconds, and 30 seconds were 12.55 µm, 12.14 µm, 11.27 µm, and 10.50 µm, respectively. The mean differences in the preclassification of neutrophils, lymphocytes, monocytes, eosinophils, and basophils in DI-60, according to the SP-50 staining conditions, were 0.88, -1.58, -0.24, 0.37, and 0.07, respectively. CONCLUSIONS: Wright-Giemsa staining of blood smears prepared on the SP-50 showed that changing the pH of the concentrated phosphate buffer to 6.6 and adjusting the staining time did not affect the results of the leukocyte differential count. However, since fan1 was used to dry the blood smear on the SP-50 and the lymphocyte size gradually decreased as the start time was delayed, it was necessary to set a start time for fan1 that did not affect the lymphocyte size.


Asunto(s)
Monocitos , Neutrófilos , Humanos , Recuento de Leucocitos , Eosinófilos , Coloración y Etiquetado
2.
Epidemiol Health ; 44: e2022024, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35209710

RESUMEN

OBJECTIVES: This study aimed to determine an effective survey method for the accurate calculation of obesity prevalence by comparing the self-reported and measured height, weight, and body mass index (BMI) using the 2018 Korea Community Healthy Survey (CHS) data. METHODS: Raw data from the 2018 CHS were used to analyze the differences, correlation, and agreement between self-reported and measured height, weight, and BMI. RESULTS: The self-reported height was over-reported than the measured height (0.59 cm greater for men and 0.71 cm greater for women), while the self-reported weight was under-reported than the measured weight (0.55 kg less for men and 0.67 kg less for women). Subsequently, the self-reported BMI was under-estimated (0.35 kg/m2 lower for men and 0.49 kg/m2 lower for women) compared with the measured BMI. The kappa statistic and agreement between measured and self-reported values per BMI category (underweight, normal, overweight, and obesity) were 0.82 and 79.6%, respectively. CONCLUSIONS: The prevalence of obesity should be calculated using the measured values provided in the CHS in order to promote local health projects based on accurate evidence.


Asunto(s)
Obesidad , Índice de Masa Corporal , Peso Corporal , Femenino , Humanos , Masculino , Obesidad/epidemiología , Reproducibilidad de los Resultados , República de Corea/epidemiología , Autoinforme , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...